External 48 VDC power supply
CAUTION
•
Input
-
Rated voltage: 36–60 VDC
-
Rated current: 0.25 A DC
•
Output
-
Rated voltage: 5 VDC ± 5%, 5W
-
Rated current: 1 A DC
-
6-inch cable terminated with 2.5 mm barrel plug, center positive
•
Isolation: 500 VDC
•
Environment: 0–40°C; 5–95% relative humidity, non-condensing
Transmission line
Single Twisted Pair
Line coding
TC-PAM (Trellis Coded Pulse Amplitude Modulation)
Line rates (DSL line)
All nx64 rates from 64 kbps up to 4.6 Mbps
Line interface
Transformer coupled, 2500 VRMS isolation
G.SHDSL physical connection
RJ-45, 2-wire polarity insensitive pins 4 and 5
Environment
Operating temp: 32–122°F (0–50°C)
Humidity: 5–95% non-condensing
Altitude: 0–15,000 feet (0–4,600 meters)
Transmission line
The external DC adaptor shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. The interconnecting cables
shall be rated for the proper voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability