Introduction; Software (Cli) Configuration; Hardware (Dip-Switch) Configuration; Rocketlink-G (Model 3088/D Shown) - Patton electronics RocketLink-G 3088 Series User Manual

G.shdsl ntu with fixed serial interface
Hide thumbs Also See for RocketLink-G 3088 Series:
Table of Contents

Advertisement

Model 3088 Series User Manual

Introduction

You can configure the RocketLink-G (see
Software configuration using command line interface (CLI) via the console port
Hardware configuration via DIP switches

Software (CLI) configuration

To use software configuration you must set all the DIP switches to the ON position before powering-up the
RocketLink-G. When all the DIP switches are set to ON the RocketLink-G will operate in software-configura-
tion mode. When set for software-configuration mode the RocketLink-G will read any configuration data pre-
viously saved to FLASH memory during system power-up. If no configuration data was previously saved to
FLASH, then the RocketLink-G will load the factory-default configuration from FLASH memory. After
power-up, you may use console commands or the Embedded Operations Channel (EOC) to modify the con-
figuration parameters.

Hardware (DIP-switch) configuration

To use DIP-switch configuration you must first set the DIP switches to a position other than all OFF or all ON
before powering-up the RocketLink-G. When all the DIP switches are set to any position other than all OFF or
all ON the RocketLink-G will operate in hardware (DIP-switch)-configuration mode. In DIP-switch-configu-
ration mode the RocketLink-G will read the DIP-switch settings during system startup and configure itself
according to the switch settings.
Once you power-up the RocketLink-G in DIP-switch mode it will operate in DIP-switch mode until powered-
down. When operating in DIP-switch mode you cannot change any configuration settings:
Changing the DIP switch settings while the device is running will not modify the operating configuration
because the RocketLink-G only reads the DIP switches during system startup.
If you attempt to modify the configuration by issuing console commands, the device will not execute your
commands. Instead, the RocketLink-G will respond with a message indicating the device is operating in
DIP-switch-configuration mode.

Introduction

figure
3) in one of two ways:
Figure 3. RocketLink-G (Model 3088/D shown)
2 • Configuration
19