Use the following connection diagram to connect the 120 ohm E1 network channel.

Connecting power

External AC universal power supply

1. Connect the power cord from the AC socket to the IEC-320 power entry connector on the universal input
power supply.
CAUTION
2. Connect the barrel plug to the Power connector on the Model 3088.
Note
The Model 3088 powers up as soon as it is plugged into an AC outlet—there
is no power switch.
Installation
RJ-48C Cable (8-Wire)
3088/T
Signal
Pin #
RX (Ring)
1
RX (Tip)
2
Shield
3
TX (Ring)
4
TX (Tip)
5
Shield
6
Figure 17. RJ-45 cable diagram for T1 connection
The external AC adaptor shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. Ensure that the AC power
cable meets all applicable standards for the country in which it is
to be installed, and that it is connected to a wall outlet which has
earth ground.