nsta ation
instructions
'I
2
3owire connections plus separate grounding connector
For use where
local codes do not permit
grounding
through
the Neutram wire.
Use approved
3--wire Power Supply Cord or a 3--wire Cable for Direct Wiring as described on page 23.
A separate I OAWG copper grounding
wire is required.
Remove the terminal
block cover @ate.
Insert the power supply cable with a UL listed strain relid through the hole provided in the cabinet
near the terminal
block. Do not tighten
strain relief screw until wiring connections
are complete.
Note: a strain relief must be used.
strain relief
S
4
5
6
7
8
9
screws
Fig.27 In ert ng the power cord
Remove center terminal
Mock screw.
Remove appliance ground
link by removing
the ground connector
screw (Green screw).
Connect a separate copper ground wire (green with yellow stripe) using the ground connector
screw (Green screw). Make sure a ring terminal
is used when connecting
the ground wire and that
the wire is firmly secured to an adequate
grounding
path.
Note: If the appliance
is
moved back to a 3-wire
installation
the ground
link must be ref tted,
Remove [ink
Fig28 Connecting
the wires
Connect the neutral wire (center) of the power supply cord to the center terminal
screw of the
terminal
block. Tighten
screw.
Connect the other wires to the upper and lower terminal
block screws marked with the letter L
Tighten
screws.
Refit terminal
block cover by inserting
the two tabs first on the rear panel of the dryer and secure
cover with securing screw.
Tighten
strain relief screws.
S
J
9
it is recommended
that a qualified
electrkian
Fig29 Refitting terminal
determine
that the ground
path is adequate
block and tightening
screws