Fisher & Paykel DE62TD1 Installation Instructions And User Manual page 24

Aerosmart clothes dryer
Table of Contents

Advertisement

nsta ation
instructions
Power supply cord requirements for UoSoA (for electric models only)
Only a UL listed power-supply cord kit a suitable length for the installation and rated 120/240 V
rain, 30 A and marked with use for clothes dryers shall be used.
This shall have ring terminals to connect to the dryer.
The UL--ratedstrain relief included with it shall be suitable for a 1%" (28.5 ram) hole.
FIG20 UL fired
power-supply
cord
3 wire
4 wire
Connecting by direct wire
Power supply cable must match power supply (4-wire or S--wire) and be:
Flexible armoured
or non-metallic
sheathed copper cable (with ground wire). All current--
carrying wires must be insulated.
10 gauge AWG solid copper wire (do not use Muminium
wire).
Suitable
length for the installation,
A UL approved
strain relief must be used.
Grounding for a direct wired appJiance
This appliance
must be connected
to a grounded
metal permanent
wiring
system, or an
equipment
grounding
conductor
must be run with the circuit conductors
and connected
to the
equipment-grounding
terminal
on the appliance.