If you are to use the Continuous Access Journal Z pair for delta resync operation as the master
journal after a power supply error occurred at the primary storage system, first resynchronize
the pair and then execute I/O operation from the host.
After the delta resync operation (when pair status has changed to Duplex), the delta resync
P-VOL must be updated from the host for longer than five minutes. This is done to insure internal
communications between the sites.
However, if remote command devices are used, the update operation needs not be performed
for five minutes or more. See
(page 135)
To restore a pair
1.
In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal Z > Pair
Operation.
2.
Click
3.
In the tree, select the CU group number or CU number for the pair. Associated pair volumes
display in the right-side list area.
NOTE:
to an error until the cause of error is removed.
4.
In the list, select a pair to resume, perform the delta resync operation, or change the status
from Hlde to Hold, right-click and select Resume Pair from the menu.
The Resume Pair dialog box displays.
5.
From the Range list, select one of the following:
Volume, to resync only the selected pair or pairs.
NOTE:
status, the pairresync command is rejected.
Mirror, to resync all pairs in the same mirror(s) as the selected pairs.
Specify the restore range. The default is Volume if two or more pairs in the same mirror are
selected. The default is Mirror if not. Note that the default setting is Mirror when the pair status
is Hold, Holding or Hlde, and in that case you cannot change the default setting.
If the following two conditions are satisfied and you click Apply, a warning message appears
and processing cannot continue:
The Preview list contains two or more pairs belonging to the same mirror.
The Range column displays Mirror for at least one of the above pairs.
74
Pair operations
"Prerequisite information for performing delta resync operation"
for details.
to change the mode from View to Modify.
The primary system does not resynchronize a pair or pairs that are suspended due
If the journal to which the specified pair belongs is in the Halting or Stopping