Change Journal Option Dialog Box - HP XP P9500 User Manual

Storageworks p9000 continuous access journal for mainframe systems
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Item
Previous
Next
Close

Change Journal Option dialog box

This dialog box lets you change the options that affect pairs in a journal. See
Access Journal Z options used by journals" (page 93)
Item
Inflow Control
Data Overflow Watch
Use of Cache
Timer Type
Description
[None]: No processing takes place when delta resync operation cannot be performed. Therefore,
the S-VOL will not be updated.
- Speed of Line: The line speed (in megabits per second) of data transfer. One of the following
appears: 256, 100, or 10.
This setting does not take effect on master journals. However, if the Business Continuity Manager
YKRESYNC REVERSE command is used to change a master journal into a restore journal, this
setting takes effect on the journal.
- EXCTG, DKC/CTRLID: Displays the following information sequentially if the journal belongs to
an extended consistency group:
The extended consistency group number
The serial number and the LDKC number (the LDKC number is enclosed by parentheses)
A slash (/), the controller ID
This column is blank if the journal does not belong to any extended consistency group.
- Remote Command Device: Displays LDEV numbers if the mirror is assigned to the remote
command device. This column is blank if the mirror is not assigned to the remote command
device.
Displays detailed information about the previous journal.
Displays detailed information about the next journal.
Closes the Journal Detail dialog box.
Description
Restrict inflow of update data to the journal volume. Yes restricts inflow, No does not restrict.
(slows delay response to hosts
Sets number of seconds for the system to monitor write data to the journal volume, after the
journal volume threshold (80%) is reached.
Stores journal data in cache memory from the restore journal (only).
Sets the type of clock used for consistency time—System, Local, None.
for complete information.
Change Journal Option dialog box 153
"Change Continuous

Advertisement

Table of Contents
loading

This manual is also suitable for:

Continuous access journal z

Table of Contents