6
CDR-1009
Probable Cause
Indicates an internal error in the ASIC hardware that may or may not degrade data traffic.
Recommended
Whenever this error occurs, restart the system at the next maintenance window.
Action
Severity
WARNING
CDR-1009
Message
<timestamp>, [CDR-1009], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip warning Level 2 type = 0x<chip error type>.
Probable Cause
Indicates an internal error in the ASIC hardware that may or may not degrade data traffic.
Recommended
Whenever this error occurs, restart the system at the next maintenance window.
Action
Severity
WARNING
CDR-1010
Message
<timestamp>, [CDR-1010], <sequence-number>,, CRITICAL, <system-name>, S<slot
number>,C<chip index>: Internal monitoring of faults has identified suspect
hardware, blade may need to be reset or replaced: fault1:<fault1_cnt>,
fault2:<fault2_cnt> thresh2:0x<threshold_used>.
Probable Cause
Indicates above normal errors observed in hardware that may or may not impact data traffic.
Recommended
Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists,
Action
replace the blade.
Severity
CRITICAL
Chapter 31, FCOE System Messages
Include the following message in the chapter, FCOE System Messages on page 205.
FCOE-1020
Message
<timestamp>, [FCOE-1020], <sequence-number>,, INFO, <system-name>, Login rejected
by FC stack.
Probable Cause
Indicates a FLOGI was sent to the FC stack by the FCoE driver but login was rejected by FC stack.
Recommended
No action is required.
Action
Severity
INFO
44
EA DRAFT: BROCADE CONFIDENTIAL
Fabric OS Documentation Updates