EXAMPLES
Add the following examples to the Example section:
To enable bottleneck detection on the logical switch with congestion alerts only:
To enable bottleneck detection on the logical switch with latency alerts only:
To enable bottleneck detection on the logical switch with both congestion and latency alerts:
To change the bottleneck detection configuration on the logical switch to allow congestion alerts only:
To change the bottleneck detection configuration on the logical switch to allow latency alerts only:
To change the bottleneck detection configuration on the logical switch to allow both congestion and
latency alerts:
To change the bottleneck detection configuration on the logical switch to disable all alerts:
To change the bottleneck detection configuration on port 5 to allow congestion alerts only; overrides
switch-wide configuration:
To change the bottleneck detection configuration on port 5 to allow latency alerts only; overrides
switch-wide configuration:
To change the bottleneck detection configuration on port 5 to allow congestion and latency alerts;
overrides switch-wide configuration:
To change the bottleneck detection configuration on port 5 to disable alerts; overrides switch-wide
configuration:
The output of the --status display has been changed to indicate which type of alert is configured. In the
section "Switch-wide alerting parameters", the output now displays which type of alert is configured.
(Previously it only displayed whether or not alerts were enabled.) In the section "Per-port overrides for
alert parameters", the abbreviations "C" and "L" indicate "congestion" and "latency". The meanings of the
abbreviations "Y" (both alerts configured) and "N" (no alerts configured) remain unchanged.
Fabric OS Documentation Updates
53-1002063-09
-lthresh latency_threshold
Specifies the severity threshold for latency that triggers an alert. The
threshold indicates the percentage of one-second intervals affected by the
bottleneck condition within the specified time window. The threshold is
expressed as the equivalent fraction between 0 and 1. The default value is
0.1. This parameter is valid only for latency alerts.
switch:admin> bottleneckmon --enable -alert=congestion
switch:admin> bottleneckmon --enable -alert=latency
switch:admin> bottleneckmon --enable -alert
switch:admin> bottleneckmon --config -alert=congestion
switch:admin> bottleneckmon --config -alert=latency
switch:admin> bottleneckmon --config -alert
switch:admin> bottleneckmon --config -noalert
switch:admin> bottleneckmon --config -alert=congestion 5
switch:admin> bottleneckmon --config -alert=latency 5
switch:admin> bottleneckmon --config -alert 5
switch:admin> bottleneckmon --config -noalert 5
5