Download Print this page

Brocade Communications Systems StoreFabric SN6500B Reference Manual page 305

Brocade fabric os mib reference v7.1.0 (53-1002750-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:

Advertisement

TABLE 106
object and OID
lldpMessageTxHoldMulti
plier
1.0.8802.1.1.2.1.1.2
lldpReinitDelay
1.0.8802.1.1.2.1.1.3
lldpTxDelay
1.0.8802.1.1.2.1.1.4
lldpNotificationInterval
1.0.8802.1.1.2.1.1.5
lldpPortConfigTable
1.0.8802.1.1.2.1.1.6
lldpPortConfigEntry
1.0.8802.1.1.2.1.1.6.1
lldpPortConfigPortNum
1.0.8802.1.1.2.1.1.6.1.1
lldpPortConfigAdminStat
us
1.0.8802.1.1.2.1.1.6.1.2
lldpPortConfigNotificatio
nEnable
1.0.8802.1.1.2.1.1.6.1.3
Fabric OS MIB Reference
53-1002750-01
Access
Description
Read-write
The time-t o-live value expressed as a multiple of the
lldpMessageTxInterval object.The actual time-to-live value used in LLDP
frames, transmitted on behalf of this LLDP agent, can be expressed by
the following formula: TTL = min(65535, (lldpMessageTxInterval *
ldpMessageTxHoldMultiplier)) For example, if the value of
lldpMessageTxInterval is 30, and the value of
lldpMessageTxHoldMultiplier is 4, then the value 120 is encoded in the
TTL field in the LLDP header.
The default value for this object is four seconds. The value of this object
must be restored from non-volatile storage after a re-initialization of the
management system.
Read-write
The object indicates the delay (in units of seconds) from when
lldpPortConfigAdminStatus object of a particular port becomes
"disabled" until re-initialization will be attempted. The default value for
this object is two seconds. The value of this object must be restored
from non-volatile storage after a re-initialization of the management
system.
Read-write
The object indicates the delay (in units of seconds) between successive
LLDP frame transmissions initiated by value or status changes in the
LLDP local systems MIB. The value for this object is set using the
following formula:
1 <= lldpTxDelay <= (0.25 * lldpMessageTxInterval)
The default value for this object is two seconds.The value of this object
must be restored from non-volatile storage after a re-initialization of the
management system.
Read-write
This object controls the transmission of LLDP notifications.
If notification transmission is enabled for particular ports, the
suggested default throttling period is 5 seconds. The value of this
object must be restored from non-volatile storage after a
re-initialization of the management system.
Not
The table that controls LLDP frame transmission on individual ports.
accessible
Not
The LLDP configuration information for a particular port. This
accessible
configuration parameter controls the transmission and the reception of
LLDP frames on those ports whose rows are created in this table.
Not
The index value used to identify the port component (contained in the
accessible
local chassis with the LLDP agent) associated with this entry. The value
of this object is used as a port index to the lldpPortConfigTable.
Read-write
The administratively desired status of the local LLDP agent.
Read-write
The object controls, on a per port basis, whether or not notifications
from the agent are enabled.
The values are as follows:
true(1) - The notifications are enabled.
false(2) - The notifications are not enabled.
16
LLDP MIB
285

Advertisement

loading