Connector Pin
1
2
3
4
5
6
7
8
9
Connector
Standard IEC
Technical
The following tables detail the technical specifications for the iPump 562 .
Specifica-

RF Characteristics

tions
RF Input
Input Frequency Range
Input Level Range
Maximum Aggregate Input Power
Input Impedance
Input VSWR
Input Noise Figure
L.O. Leakage at Input
Demodulator
DVB-S QPSK
DVB-S2 QPSK
DVB-S2, 8PSK
Max Symbol-rate
www.wegener.com
External Input/Output Interfaces
Contact Closure GPIO DB-9 Female
Input/Output
Alarm Common
Alarm Normally Open
Contact Closure Common
No Connection
Input
Contact Closure GPIO Input
(Factory use only)
Alarm Normally Closed
Contact Closure Normally Closed
Contact Closure Normally Open
NA
Ground
Power DC IN 12 V 5 A
Input/Output
Input
115 or 230 V AC

Table 1.3: iPump 562 RF Characteristics

RF Characteristics
Connector Type F
950 - 2150 MHz
-25 to -65dBm
-8 dBm at max input signal
75 ohms
< 2.5:1
8 dB MAX at minimum input level
< -55 dBm
FEC Rate 1/2, 2/3, 3/4, 5/6, or 7/8 (1.0 to 45 MBaud) ½, 2/3,
¾, 4/5, 5/6, 7/8, 9/10 (2 to 30 MBaud) 2/3, ¾, 5/6, 8/9, 9/10
(3 to 30 MBaud) Convert Symbol Rate Fs to Transport Rate
Ft by: (2R*Fs)*(188/204)=Ft, where 'R' is inner FEC code
ratio, either R=1/2, 2/3, 3/4, 5/6, or 7/8.
S2 = 30 Msps; S1 = 45 Mbps