6.26

Load Default Value "LD 00H 00H"

Format:
LD 00H 00H
Function:
-
The following procedures are executed:
-
The power on default environment memorized in NVRAM is loaded to default
environment.
-
NVRAM indicates EEPROM, DIP-SW, and ROM. The power on default
environment is read from the appointed NVRAM with each setting item, and
the default environment is loaded.
-
However, settings by following commands are not changed by this command.
(not loading)
-
SM command (set the status transmitting mode)
-
Baud rate setting value for the MAC serial by the BR command (set baud rate)
is not initialized. (The built-in EIA-232D serial interface intended to be
initialized.)
-
This command is only valid in remote mode.