Error: Hdd Blinking Amber, Chm Blinking Amber; Error: Hdd Blinking Green, Chm Steady Green; Interraid-8 And Interraid-12; Error: Information Control Panel Displays, "Hardware Error - Intergraph InterRAID-12 Hardware User's Manual

Disk array cabinet
Table of Contents

Advertisement

Error: HDD blinking amber, CHM blinking amber

Reason
Failed disk drive. Disk array not in
a fault-tolerant state.

Error: HDD blinking green, CHM steady green

Reason
Disk drive not assigned into a pack.

InterRAID-8 and InterRAID-12

The following tables provide troubleshooting guidelines specifically for the InterRAID-8 and
InterRAID-12 disk arrays.

Error: Information Control Panel displays, "Hardware Error"

Reason
Component failure.

Error: Power-On Self Test (POST) fails

Reason
Component failure.
Solution
Replace the disk drive, rebuild the disk array.
Solution
Assign the disk drive to a pack, if desired; otherwise,
the hot spare will be used in the event of a disk
failure. Refer to the appropriate chapter that
corresponds to the installed RAID controller.
Solution
Identify the failed component using the "Component
Status" menu of the Information Control Panel menu.
Replace the failed component according to Chapter 8.
Solution
Select "POST Results" in the Information Control
Panel menu. Locate the failed component.