4.
Go to the next section.
Setting digital trunk boards to use the clocking signal sent by the
telephone company
Select an Intel Dialogic telephony board with a digital line connected to the telephone company
to provide the clocking signal to the other trunk boards connected via the bus ribbon cable in the
TeleVantage Server.
1.
2.
C
7. I
HAPTER
NSTALLING
The
parameter contains the base memory address assigned to Intel
BLTAddress
Dialogic. Verify that this base memory address is not being used by another board or
program.
Note:
If there are other SCSI devices attached to the PC, they probably use the same
base memory address (the default is d8000). It is easier to change the base memory
address for the other devices than to change the address assigned to Intel Dialogic in
DCM.
To set your trunk boards to use the clocking signal sent from the telephone company,
in the main DCM dialog box, under
Select the parameter
Primary Master FRU (User Defined)
analog trunk board from the
I
D
B
NTEL
IALOGIC
TDM Bus
drop-down list.
Value
D
OARD
RIVERS
, double-click
.
Bus-0
and then select a digital or
7-17