Vertical TeleVantage 7.5 Install Manual page 140

Installing intel telephony components
Hide thumbs Also See for TeleVantage 7.5:
Table of Contents

Advertisement

Model number
DM/IPx
DI/SI32
DISI/xR2
HDSI/x
DM/V160LP,
DM/V160LPEU
DM/V2400A
DI0408LSAR2
2.
C-4
Do one of the following:
Q If the board does not pass POST.
again. If it still fails, contact your Technical Support representative.
Q If the board passes POST.
The diagnostic settings in the following table indicate that a DM3 board has passed
POST:
Type
IP telephony board
Station board
Station board
Station board
Analog trunk board
Conference bridge board
Integrated trunk and station
board
To verify whether Windows is able to detect the board and IRQ, run PCITree, a utility
that lists installed PCI boards. PCITree may show boards that do not appear in
Windows Device Manager.
You can download PCITree from the following location:
http://www.pcitree.de/
Intel Dialogic PCI boards are identified by one of the following Vendor IDs (VID):
Q 10b5 PLX Technology.
Q 12C7 Dialogic Corp.
To display the VID for a board, click on the board in the PCITree main window. The
VID is displayed in the PCI Device pane at the upper right of the PCITree window.
Reseat or replace the board and run DCM
Go to the next step.
LED settings after successful POST
All lights are off.
2 yellow lights are blinking, green and red lights are
solid on.
All lights are off.
Green light stays on.
Identifies a DM3 board.
Identifies a non-DM3 board.