Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G =
Combustible
G
6" (152 mm)
Noncombustible
V
2" (51 mm)
Balcony -
with no side wall
M
V
M =
Combustible &
Noncombustible
12" (305 mm)
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3' (914 mm) minimum between termination caps. 2. All
mechanical air intakes within 10' (1 m) of a termination cap must be a minimum of 3' (914 mm) below the termination cap. 3. All
gravity air intakes within 3' (914 mm) of a termination cap must be a minimum of 1' (305 mm) below the termination cap.
Fig. 10 Termination clearances.
NOTE: Use only venting systems and components
as certified with the appliance. Use of uncertified vent
systems or components will void the warranty and may
compromise the operation of the fireplace, its systems,
and components as certified with the appliance.
Top of Vent
2" (51mm)
1" (25mm)
Fig. 11 Vent clearances.
76657
T181
vent clearances
12/3/03 djt
Outside Corner
F =
Combustible
6" (152 mm)
Noncombustible
V
2" (51 mm)
F
Balcony -
with perpendicular side wall
M
V
P
Combustible &
Noncombustible
M = 24" (610 mm)
P = 20" (508 mm)
Combustibles
NOT Allowed in
Shaded Area
4" Dia. Flue
7" Dia. Intake
Vent
1"
(25mm)
T181
Temco DV1000/1200/1400 Series
Alcove Applications*
C
E
= Min. 6" (152 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No.
of Caps
1
2
3
4
D
= # of Termination caps x 3
Min.
C
= (2 / # termination caps) x D
Max.
0
3'
32'
30'
25'
15'
10'
46"
5'
(1168mm)
33¹⁄₂"
(851mm)
0
* Min. Refer to Chart on Page 6
Fig. 12 Venting graph.
D
C
V
E
O
D
C
Min.
Max.
3' (914 mm)
2 x D
Actual
6' (1.8 m)
1 x D
Actual
9' (2.7 m)
2/3 x D
Actual
12' (3.7 m)
1/2 x D
Actual
Actual
15'
5'
10'
A vent guard should be
used whenever the termina-
tion is lower than the speci-
*
fied minimum or as per local
codes
T180
DV vent graph
12/3/03 djt
584-15
T180
11