This saw is designed to use a 3450 RPM motor only.
Do not use any motor that runs faster than 3450
RPM It is wired for operation
on 110-120 volts, 60
Hz.,
Alternating
current.
IT
MUST
NOT
BE
CONVERTED
TO OPERATE ON 230 VOLTS.
The Black and Red motor leads are connected
to
quick connect tabs "A" and "B" on terminal
board.
WARNING:
Do not change any of these connec-
tions with current on.
A
TI
POWER LEAD
POWER LEAD
BLACK
®
GREEN
GROUND
SCREW
RED
CAUTION: Do not use blower or washing machine
motors
or any motor
with an automatic
reset
overload protector as their use may be hazardous.
For replacement
motor refer to parts list in this
manual.
CONNECTING
TO POWER SOURCE OUTLET
This saw must be grounded while in use to protect
the operator from electrical shock.
If power cord is worn or cut, or damaged in anyway,
have it replaced
immediately.
If your saw is for use on less than 150 volts it has a
plug that looks like below.
This saw is equipped
with a 3-conductor cord and
grounding
type plug which has a grounding
Prong,
approved
by Underwriters'
Laboratories
and th_
Canadian
Standards
Association.
The
ground
conductor
has a green lug and is attached to the to(_
housing
at one end and to the ground prong in the
attachment
plug at the other end.
This plug requires a mating 3-conductor
grounded
type outlet as shown.
If the outlet you are planning to use for this saw is of
the two prong type DO NOT REMOVE OR ALTER
THE GROUNDING
PRONG IN ANY MANNER.
Use
an adapter
as shown
and
always
connect
th_
grounding
lug to a known ground.
It is recommended
that
you
have
a qualified
electrician
replace
the TWO prong
outlet
with
a
properly
grounded
THREE prong outlet.
An
adapter
as
shown
below
is
available
for
connecting
plugs to 2-prong receptacles. The green
grounding
lug extending
from the adapter must be
connected
to a permanent
ground
such as to a
properly
grounded
outlet box.
An adapter as illustrated
is available for connecting
plugs to 2-prong
receptacles.
GROUNDING
LUG
/
!
s,,
ADAPTER
3-PRONG
PLUG
\
GROUNDING
PRONG
GROUNDED
3-PRONG
OUTLET
Plug power cord of fully assembled
saw into 110-
120V properly grounded
type outlet protected
by a
15-amp. time delay or Circuit-Saver
fuse or circuit
breaker.
IF YOUR ARE NOT SURE THAT YOUR OUTLET IS
PROPERLY GROUNDED,
HAVE IT CHECKED
BY
A QUALIFIED
ELECTRICIAN.
WARNING:
DO
NOT
PERMIT
FINGERS
TO
TOUCH
THE
TERMINALS
OF
PLUG
WHEN
INSTALLING
OR REMOVING
THE PLUG TO OR
FROM THE OUTLET.
WARNING: IF NOT PROPERLY GROUNDED
THIS
POWER
TOOL
CAN
INCUR
THE
POTENTIAL
HAZARD
OF ELECTRICAL
SHOCK
PARTICU-
LARLY WHEN USED IN DAMP LOCATIONS,
IN
PROXIMITY TO PLUMBING,
OR OUT OF DOORS.
WARNING:
THE
GREEN
GROUNDING
LUG
EXTENDING
FROM
THE ADAPTER
MUST
BE
CONNECTED
TO
A
PERMANENT
GROUND
SUCH AS TO A PROPERLY GROUNDED
OUTLET
BOX. NOT ALL OUTLET BOXES ARE PROPERLY
GROUNDED.
If you are not sure that your outlet box is properly"
grounded,
have it checked by a qualified electrician.
NOTE: The adapter illustrated
is for use only if you
already
have
a
properly
grounded
2-prong
receptacle.
The use of any extension cord will cause some loss
of power. To keep this to a minimum and to prevent
ever-heating
and motor
burn-out,
use the table
below to determine the minimum
wire size (A.W.G,)
extension
cord.
Use only 3 wire extension
cord_
which have 3 prong grounding
type plugs and 3-
pole receptacles
which will accept the plug on the
saw.
The
motor
must
rotate
COUNTERCLOCKWISE
when viewed from the shaft end.
1 H.P. MOTOR 110-120V
Extension Cord Length
Wire Size A.W.G_:
Up to 50 Ft.................
14
IF AN ELECTRICAL
SHOCK OCCURS THERE IS
50 to 100 Ft ................
12
THE POTENTIAL
OF A SECONDARY
HAZARD
.......
t
........
/ UU
tUU
r
SUCH
AS YOUR HANDS
CONTACTING
THE
-
.
.......
10
SAWBLADE.
200 - 400 Ft.................
8