Lanview Leds - Enterasys 2S4082-25-SYS Hardware Installation Manual

Nac controller
Table of Contents

Advertisement

Table 5-1 LANVIEW LEDs
LED
Color
MGMT
None
Green
Amber
CPU
None
Amber
Green
Red
Green
and
Amber
Amber
and off
RX
None
(Receive)
Green
Amber
Red
State
Off. This module is NOT the
Management Module.
Solid. This module is the
designated Management
Module.
Flashing. This is a temporary
indication that the module is
saving data.
Power off.
Blinking. Module in process of
booting.
Solid. Testing.
Blinking. Image starts running.
Solid. Functional.
Solid. Processor in reset.
Blinking. Indicates that the
module is in the process of
shutting down.
Alternating (67% on, 33% off).
Indicates that a shutdown
process has completed. This
indication will remain for 60
seconds before automatically
restarting.
No link. No activity. Port
enabled or disabled.
Solid. Link present, port
enabled, no traffic is being
received by the interface.
Flashing. Link present, port
enabled, traffic is being received
by the interface.
Blinking. Indicates collisions.
This indication is only supported
on 10/100 ports.
Enterasys NAC Controller Hardware Installation Guide 5-3
Recommended Action
None.
None.
None.
Ensure chassis has adequate power.
None.
If the LED remains amber for several
minutes, contact Enterasys Networks for
technical support.
None.
None.
None.
None. This state is activated when the
OFFLINE/RESET switch is pressed for less
than 1 second to a start the process of an
orderly shutdown.
While in this state, do not remove any
chassis.
While in this state, you have 60 seconds to
safely remove the chassis from the chassis.
None.
None.
None.
Contact Enterasys Networks for technical
support.
Using LANVIEW

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

7s4280-19-sys

Table of Contents