Emerson Rosemount 3300 Series Reference Manual page 40

Guided wave radar level and interface transmitters
Hide thumbs Also See for Rosemount 3300 Series:
Table of Contents

Advertisement

Rosemount 3300 Series
L>46.5 in. (1180 mm)
20.5 < L<46.5 inch
(520 mm< L <1180 mm)
15.7< L<20.5 inch
(400< L<520 mm)
3-16
Rigid Twin Lead
The spacers are put closer together at the probe end. The maximum amount
that can be cut away is related to the ordering length L.
To cut a Rigid Twin Lead probe do the following:
L
Max. shortening length:
19.7 in. / 500 mm
Minimum probe length
20.5 inches / 520 mm
L
Minimum probe length
15.7 inches / 400 mm
L
Reference Manual
00809-0100-4811, Rev CA
1. Cut the rods to the desired length:
You may cut up to 19.7 inch (500
mm) from the probe end for probe
length L above 46.5 in. (1180 mm).
For probe length
20.5 to 46.5 in. (520 to 1180 mm)
the minimium length is
20.5 in. (520 mm).
For probe length 15.7 to 20.5 in.
(400 to 520 mm) the minimium
length is 15.7 in. (400 mm).
2. Update the transmitter configuration
to the new probe length, see "Probe
Length" on page 4-9.