Emerson Rosemount 3300 Series Reference Manual page 124

Guided wave radar level and interface transmitters
Hide thumbs Also See for Rosemount 3300 Series:
Table of Contents

Advertisement

Rosemount 3300 Series
Spare parts list Probe Model 3301/3302
Model
Product Description
3309
Spare probe
Code
Signal Output
N
Not applicable
Code
Housing Material
N
Not applicable
Code
Conduit Threads/Cable Threads
0
Not applicable
Code
Operating Temperature and Pressure
S
Standard: -15 psig (-1 Bar) to 580 psig (40 Bar) @ 302 °F (150 °C)
H
High Temp / High Pressure
P
High Pressure
Code
Material of Construction: Process Connection/Probe
1
316 / 316L SST (EN 1.4404), Teflon (PTFE, PFA)
2
Hastelloy C276, Teflon (PTFE, PFA). Available for probe type 3A, 3B and 4A (with plate design if not threaded)
3
Monel 400, Teflon (PTFE, PFA). Available for probe types 3A, 3B and 4A (with plate design if not threaded)
7
PTFE Covered Probe and Flange valid for probe 4A, 5A flanged version only (with plate design)
8
PTFE Covered Probe and Flange valid for probe 4A, 5A
Code
Sealing, O-ring Material (Consult factory for other
o-ring materials)
V
Viton
E
Ethylene Propylene
K
Kalrez 6375
B
Buna-N
N
None (HP/HTHP)
Code
Probe Type
1A
Rigid Twin Lead.
2A
Flexible Twin Lead with weight
3A
Coaxial
3B
Coaxial perforated, for interface or easier
cleaning
4A
Rigid Single Lead
5A
Flexible Single Lead with weight d=4 mm
5B
Flexible Single Lead with chuck d=4 mm
Code
Probe Length Unit
E
English (feet, inch)
M
Metric (meters, centimeters)
Code
Total Probe Length
xx
0-65 feet or 0-20 m
Code
Total Probe Length
xx
0-11 inches or 0-99 centimeters
(1) Process seal rating. Final rating depends on flange and O-ring selection, see "Process Temperature and Pressure Rating" on page A-4.
(2) Extra length for fastening is added in factory.
(3) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit
(see Model String Example). If tank height is unknown, please round up to an even length when ordering - probes can be cut to exact length in field.
Maximum allowable length is determined by process conditions.
A-20
Applicable
for Model
3301 & 3302
3301 & 3302
3301
3301 & 3302
3301
3301
(2)
3301
(3)
(feet/m)
(3)
(inch/cm)
(1)
Allowable Process
Probe Length
Connection
Flange or 1.5 " Thread
Min: 1 ft 11 inch (0.6 m)
Max: 9 ft 10 inch (3 m)
Flange or 1.5 " Thread
Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
Flange or 1", 1.5 " Thread Min: 1 ft 3 inch (0.4 m)
Max: 19 ft 8 inch (6 m)
Flange or 1", 1.5 " Thread Min: 1ft 3 inch (0.4 m)
Max: 19 ft 8 inch (6 m)
Flange or 1", 1.5 " Thread Min: 1 ft 11 inch (0.6 m)
Max: 9 ft 10 inch (3 m)
Flange or 1", 1.5 " Thread Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
Flange or 1", 1.5 " Thread Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
Reference Manual
00809-0100-4811, Rev CA
February 2006

Advertisement

Table of Contents
loading

Table of Contents