Emerson Rosemount 3300 Series Reference Manual page 119

Guided wave radar level and interface transmitters
Hide thumbs Also See for Rosemount 3300 Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4811, Rev CA
February 2006
Model Code 3302, Level and Interface in Liquids
Model
Product Description
3302
Guided Wave Radar Level and Interface Transmitter
Code
Signal Output
H
4-20 mA with HART
Code
Housing Material
A
Polyurethane-covered Aluminum
Code
Conduit / Cable Threads
1
½ - 14 NPT
2
M20 x 1.5 adapter
3
PG 13.5 adapter
Code
Operating Temperature and Pressure
S
- 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C)
H
High Temp / High Pressure
to ANSI Class 2500 (Probe Type 3A, 3B and 4A)
P
High Pressure
according to ANSI Class 2500 (Probe Type 3A, 3B and 4A)
Code
Material of Construction
1
316 / 316 L SST (EN 1.4404)
®
2
Hastelloy
C-276 (UNS N10276). Available for probe type 3B and 4A.
®
3
Monel
400 (UNS N04400). Available for probe type 3B and 4A
7
PTFE covered probe and flange. Available for probe type 4A, Flanged version
8
PTFE covered probe. Available for probe type 4A
Code
Sealing, O-ring Material (Consult factory for other o-ring materials)
(4)
N
None
®
V
Viton
fluoroelastomer
E
Ethylene Propylene
®
K
Kalrez
6375 perfluoroelastomer
B
Buna-N
Code
Probe Type
1A
Rigid Twin Lead
2A
Flexible Twin Lead with weight
3B
Coaxial for interface measurements
4A
Rigid Single Lead
Code
Probe Length Units
E
English (feet, inch)
M
Metric (meters, centimeters)
Code
Total Probe Length
xx
0 - 77 ft or 0-23 m
Code
Total Probe Length
xx
0 - 11 inch or 0-99 cm
(1) Process seal rating. Final rating depends on flange and O-ring selection. See "Process Temperature and Pressure Rating" on page A-4.
(2) Requires option None for sealing (no O-ring). Only for SST (Material of Construction model code 1).
(3) For other materials, consult factory.
(4) Requires High Temperature High Pressure (code H) or High Pressure (code P) probe.
(5) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit. If
tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions.
®
communication
(2)
: 2940 psi @ 750 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and 345 bar @ 38 °C) according
(2)
. Max 500 °F (200 °C): 3500 psi @ 500 °F and 5000 psi @ 100 °F (243 bar @ 200 °C and 345 bar @ 38 °C)
(3)
: Process Connection / Probe
(5)
(feet/m)
(5)
(inch/cm)
Rosemount 3300 Series
(1)
Process Connection
Flange or 1.5 in. Thread
Flange or 1.5 in. Thread
Flange, 1 or 1.5 in. Thread
Flange, 1 or 1.5 in. Thread
Probe Lengths
Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
Min: 3 ft 4 in. (1 m). Max: 77 ft 1 in. (23.5 m)
Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
A-15

Advertisement

Table of Contents
loading

Table of Contents