Step 2
Orienting the Sensor
The sensor will function properly in any orientation if the sensor tubes remain filled with process fluid.
Micro Motion recommends orienting ELITE sensors as shown in Table 3.
Table 3
Recommended sensor orientations
Sensor model
CMF010
CMF025, CMF050,
and CMF100
CMF200, CMF300,
CMF400, and
CMFHC3
Flow direction arrow
The sensor has a flow direction arrow (see Figures 1–4) to help you configure the transmitter for flow
direction. If possible, install the sensor so that the flow direction arrow matches actual process flow.
Vertical pipeline
If the sensor is installed in a vertical pipeline, liquids and slurries should flow upward through the sensor.
Gases may flow upward or downward.
10
Application
All applications
Liquids
Gases and slurries
Liquids
Gases
Slurries
Recommended orientation
Tubes flat
Horizontal pipeline
Tubes down
Horizontal pipeline
Tubes up
Horizontal pipeline
Tubes down
Horizontal pipeline
Tubes up
Horizontal pipeline
Flag mount
Vertical pipeline
®
®
Micro Motion