F" Group: Main Profile Parameters - Hitachi L100 Series Instruction Manual

Hide thumbs Also See for L100 Series:
Table of Contents

Advertisement

3–8

"F" Group: Main Profile Parameters

"F" Group: Main Profile Parameters

The basic frequency (speed) profile is
defined by parameters contained in the "F"
Group as shown to the right. The set
running frequency is in Hz, but accelera-
tion and deceleration are specified in the
time duration of the ramp (from zero to
maximum frequency, or from maximum
frequency to zero). The motor direction
parameter determines whether the keypad
Run key produces a FWD or REV command. This parameter does not affect the intelli-
gent terminal [FWD] and [REV] functions, which you configure separately.
Acceleration 1 and Deceleration 1 are the standard default accel and decel values for the
main profile. Accel and decel values for an alternative profile are specified by using
parameters A_92 through A_93. The motor direction selection (F_04) determines the
direction of rotation as commanded only from the keypad.
Func.
Name /
Code
SRW Display
F_01 Output frequency
setting
TM 000.0
F_02 Acceleration 1 time
setting
ACC 1
F_03 Deceleration 1 time
setting
DEC 1
F_04 Keypad Run key routing Two options; select codes:
INIT DOPE
"F" Function
Description
Standard default target
frequency that determines
constant motor speed,
0.0Hz
range is 0 to 360 Hz
Standard default acceleration,
range is 0.1 to 3000 sec.
0010.0s
Standard default deceleration,
range is 0.1 to 3000 sec.
0010.0s
00... Forward
FWD
01... Reverse
Output
F 02
frequency
F 01
0
Run
Mode
–FE
Edit
(CE)
(UL)
0.0
10.0
10.0
00
F 03
t
Defaults
–FU
–FR
Units
(Jpn)
0.0
0.0
Hz
10.0
10.0
sec.
10.0
10.0
sec.
00
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents