NOTE: When DC braking is performed, the inverter automatically holds the carrier
frequency at 1 kHz.
NOTE: The carrier frequency setting must stay within specified limits for inverter-motor
applications that must comply with particular regulatory agencies. For example, a
European CE-approved application requires the inverter carrier to be less than 5 kHz.
B_84, B_85: Initialization codes – These functions allow you to restore the factory
default settings. Please refer to
B_86: Frequency display scaling – You can convert the output frequency monitor on
D_01 to a scaled number (engineering units) monitored at function D_07. For example,
the motor may run a conveyor that is monitored in feet per minute. Use this formula:
Scaled output frequency (D_07)
"B" Function
Func.
Name /
Code
SRW Display
B_32 Reactive current setting Calibrate detection of motor's
IO 0.00A
B_81 [FM] terminal analog
meter adjustment
ADJ
B_82 Start frequency adjust-
ment
Fmin
0.5Hz
B_83 Carrier frequency
setting
CARRIER
05.0kHz
B_84 Initialization mode
(parameters or trip
history)
INIT MODE
B_85 Country code for initial-
ization
INIT SEL
"Restoring Factory Default Settings" on page
=
Description
no load (reactive) current to
improve D_02 display
accuracy, range is 0 to 32
Amperes
Adjust 8-bit gain to analog
meter connected to terminal
[FM], range is 0 to 255
080
Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz
Sets the PWM carrier (internal
switching frequency), range is
0.5 to 16.0 kHz
Select the type of initialization
to occur, two option codes:
00 ...Trip history clear
01 ...Parameter initialization
TRP
Select default parameter values
for country on initialization,
four options, option codes:
USA
00 ...Japan version
01 ...Europe version
02 ...US version
03 ...reserved (do not set)
L100 Inverter
Output frequency (D_01) Factor (B_86)
Run
Mode
–FE
Edit
(CE)
58% rated current
80
0.5
5.0
00
01
3–29
6–8.
×
Defaults
–FU
–FR
Units
(UL)
(Jpn)
A
80
80
0.5
0.5
Hz
5.0
12.0
kHz
00
00
02
00