NPort IA5150/5250 Series User's Manual

UDP Mode

Packing length
Setting
0 to 1024
Default = 0, The Delimiter Process will be followed, regardless of the length of the data packet. If
the data length (in bytes) matches the configured value, the data will be forced out. The data length
can be configured for 0 to 1024 bytes. Set to 0 if you do not need to limit the length.
Delimiter 1
Setting
00 to FF
Delimiter 2
Setting
00 to FF
Once the NPort IA5150/5250 receives both delimiters through its serial port, it immediately packs
all data currently in its buffer and sends it out the NPort IA5150/5250's Ethernet port.
ATTENTION
Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size
of the serial data received is greater than 1 KB, the NPort IA5150/5250 will automatically pack
the data and send it to the Ethernet. However, to use the delimiter function, you must at least
enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function
will not work properly.