Moxa Technologies NPort IA5150 Series Quick Installation Manual

Moxa Technologies NPort IA5150 Series Quick Installation Manual

Hide thumbs Also See for NPort IA5150 Series:

Advertisement

Quick Links

NPort IA5150/5250 Series
Quick Installation Guide
Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
Edition 6.0, April 2016
Technical Support Contact Information
www.moxa.com/support
 2016 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802051500214
*1802051500214*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NPort IA5150 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Moxa Technologies NPort IA5150 Series

  • Page 1: Quick Installation Guide

    NPort IA5150/5250 Series Quick Installation Guide Edition 6.0, April 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0 Tel: +886-2-8919-1230 Fax:...
  • Page 2: Package Checklist

    DR-120-24: 120W/5A DIN-rail 24 VDC power supply with 88 to 132 • VAC/176 to 264 VAC input by switch Note: Notify your sales representative if any of the above items are missing or damaged. NPort IA5150 Series Appearance - 2 -...
  • Page 3 NPort IA5250 Appearance Reset Button—Press the Reset button for 5 seconds to load factory defaults. Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off.
  • Page 4: Hardware Installation Procedure

    Hardware Installation Procedure STEP 1: After removing the NPort IA from the box, the first thing you should do is connect the power adapter. Connect the 12-48 VDC power line with the NPort IA’s terminal block, or connect the DIN-rail power supply with the NPort IA’s terminal block.
  • Page 5 Pin Assignments and Cable Wiring RS-232/422/485 (Male DB9) Pinouts RS-232 RS-422/RS-485 (4W) RS-485 (2W) TxD-(A) – TxD+(B) – RxD+(B) Data+(B) RxD-(A) Data-(A) – – – – – – – – – 4W/2W RS-485/RS-422 (Terminal Block) Pinouts RS-422/ RS-485 (2W) RS-485 (4W) –...
  • Page 6 Female DB9 to Male DB25 ATEX and IECEx Information 1. Certificate number: DEMKO 07 ATEX 0690059x 2. Ambient range (-40°C ≤ Tamb ≤ 75°C) 3. Certification string (Ex nA IIC T3) 4. Standards covered (EN60079-0:2006, EN60079-15:2005, IECEx UL 13.0023X, IEC 60079-0 Ed. 6, IEC 60079-15 Ed. 4) 5.

This manual is also suitable for:

Nport ia 5250 series

Table of Contents