2.14.3 Advancing Movement of the Feed Dogs

30
3
For good stitch drawing the feed dogs should, after exceeding the
upper needle bar dead center, still conduct a slight "subsequent
advance".
Caution Risk of Injury!
Before adjusting turn the main switch off.
Advance eccentric for the rear feed dog
Loosen the screws of the advance eccentric 1.
Arrest the handwheel in position B.
Insert gauge 8 into the slit 2 on the advance eccentric.
Turn the advance eccentric so that the edges of the gauge touch
on the stitch regulator guide 3.
Tighten the screws of the advance eccentric again.
Check the axial play of the lower shaft.
Attention!
By maximum transport length the feed dog may not strike the
needle plate slot.
Advance eccentric for the forward feed dog
Set the slit of the advance eccentric parallel to the left advance
eccentric.
1
2
Gauge 8