CHAPTER 3
2. Removal of the separation pad
1) Remove the cassette.
2) Lock the lifting plate by pushing it
down.
3) Unhook the 4 claws, and then remove
the separation pad.
4) Remove the spring from the pad.
Claws
Separation pad
Figure 3-9-4
< Note for reassembly >
When installing the separation pad, be sure
to set the spring securely.
3 - 30
3. Removal of the pick-up drive unit
1) Remove the pick-up roller according to
the steps 1) through 5) on page 3-29.
2) Unhook the 4 claws, and then remove
the cover.
Claws
Cover
Figure 3-9-5
3) Disconnect the 3 connectors, remove
the 2 screws, and then remove the
paper feeder PCB.
Connectors
Screws
Paper feeder PCB
Figure 3-9-6