Table 2. Power-supply LEDs
Power-supply LEDs
AC
DC
Error
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
On
Off
Off
On
Off or
On
Flashing
On
On
Off
On
On
On

Server power features

When the server is connected to a power source but is not turned on, the operating
system does not run, and all core logic except for the integrated management
module (IMM) is shut down; however, the server can respond to requests from the
IMM, such as a remote request to turn on the server. The power-on LED flashes to
indicate that the server is connected to power but is not turned on.
Turning on the server
Approximately 3 minutes after the server is connected to power, the power-control
button becomes active, and one or more fans might start running to provide cooling
while the server is connected to power. You can turn on the server and start the
operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
20
System x3650 M2 Type 7947: Installation and User's Guide
Description
Action
No ac power to
1. Check the ac power to the server.
the server or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
No ac power to
1. Replace the power supply.
the server or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source
source.
and the power
supply had
detected an
internal problem
Faulty power
Replace the power supply.
supply
Faulty power
Replace the power supply.
supply
Power supply not
1. Reseat the power supply.
fully seated,
2. If the 240V failure LED on the system
faulty system
board is lit, have the system board
board, or faulty
replaced (trained service technician
power supply
only).
3. If the 240V failure LED on the system
board is not lit, replace the power
supply.
Faulty power
Replace the power supply.
supply
Normal operation
Power supply is
Replace the power supply.
faulty but still
operational
Notes
This is a normal
condition when no
ac power is present.
This happens only
when a second
power supply is
providing power to
the server.
Typically indicates
that a power supply
is not fully seated.