Troubleshooting
Clearing the System Configuration
To clear the system configuration:
1. Power down the server blade:
a. Press the Power On/Standby button on the front of the server blade.
b. Use the virtual power button feature in the iLO remote console.
2. Disconnect the server blade from all power sources:
a. Remove the server blade from the server blade enclosure and set it on a flat,
level surface.
b. Disconnect the server blade from the diagnostic station.
3. Remove the access panel. Refer to the "Accessing Internal Server Blade
Components" section in Chapter 1, "Installing the Server Blade and Options."
4. Change position 6 of SW4 to on.
5. Install the access panel. Refer to the "Preparation Procedures" section in
Chapter 1, "Installing the Server Blade and Options."
6. Connect the server blade to system power:
a. Install the server blade in the server blade enclosure.
b. Connect the server blade to the diagnostic station.
7. Power up the server blade:
a. Press the Power On/Standby button on the front of the server blade.
b. Use the virtual power button feature in the iLO remote console.
8. Wait for the POST message that prompts you to change the switch setting:
Maintenance switch detected in the "On" position.
Power off the server and turn switch to the "Off" position.
9. Repeat steps 1 through 3.
D-12
HP ProLiant BL20p Generation 2 Server Blade Setup and Installation Guide