Configuring and Deploying Server Blades
Refer to the ProLiant Essentials Rapid Deployment Pack CD for information on
installing and running the Survey Utility. After you run the Survey Utility, you can
view the IML by loading the output of the utility (typically called SURVEY.TXT) into
a text viewer such as Microsoft Notepad. The event list follows the system slot
information. After you open the text file, you can print it using the print feature of the
viewer.
List of Events
The event list displays the affected components and the associated error messages.
Though the same basic information displays, the format of the list may differ
depending on whether you view it from within Insight Manager 7 or from within
Survey Utility.
Table 2-2 identifies the event types (affected components) and associated event
messages for server blades.
Table 2-2: Server Blade Event Messages
Event Type
Machine Environment
Fan failure
Overheat condition
Main Memory
Correctable error
threshold exceeded
Processor
Correctable error
threshold exceeded
Uncorrectable error
2-24
Event Message
System Fan Failure (Fan X, Location)
System Overheating (Zone X, Location)
Corrected Memory Error threshold passed (Slot X, Memory
Module X)
Corrected Memory Error threshold passed (System Memory)
Corrected Memory Error threshold passes (Memory Module
unknown)
Processor Correctable Error threshold passed (Slot X, Socket X)
Processor Uncorrectable internal error (Slot X, Socket X)
HP ProLiant BL20p Generation 2 Server Blade Setup and Installation Guide
continued