Auto Media Sensor Calibration

Auto Media Sensor Calibration automatically establishes the optimum sensing values for the
media you are using in the printer.
Note:
Before calibrating, be sure the media sensor is set for the appropriate
media type, see Section 4.5.2; also, ensure that the Printhead Carrier Assembly is
latched down and the cover is closed.
To automatically calibrate the media sensor:
1.
With the desired media loaded, hold the
Continue to hold the button until the
2.
Next press the
calculate the TOF Delta and Low values to be used.
3.
Upon completion, one of the following lights will flash five times to denote the result of the
auto calibration attempt:
STOP
ERROR
fail proceed to Section 4.7.2.
Note:
If you wish to discard the changes and revert back to the previous
calibration simply turn off the printer before Step 4.
4. Now save the changes and resume
simultaneously and briefly. Wait until the
Calibration Mode – Button Functions
PAUSE
button. The printer will feed approximately ten inches of media to
light = Successful calibration. Proceed to Step 4.
light = Unsuccessful calibration, try again. If the calibration continues to
CANCEL
button while powering up the printer.
STOP
light turns off then release it.
by pressing the
STOP
light goes off.
PAUSE
CANCEL
+
buttons
4-17 Rev A