Changing the Polling Interval
Changing the Polling Interval
You can change the responsiveness of Fault Management by changing the
polling intervals. If you:
Increase the polling interval, network traffic may decrease
Decrease the polling intervals, network traffic may increase
You need to find a balance between responsiveness and network traffic.
The polling interval determines the amount of time that Fault Management's
polling program is in the sleep mode. You can change the polling interval
as follows:
1. Open the following file:
/usr/OV/OneVision/DG3Poll/Dg3poll
2. Overtype the number of seconds in the following line:
Dg3poll.pollInterval: 300 seconds
The range is 0 through 1800 seconds (30 minutes.) The default is 300
seconds.
You change the polling interval by changing the number of seconds in this
line. (The larger the number, the slower the polling rate.)
Changing Default Values
Fault Management allows you to change the default values that are
delivered with your application. You can use either of the following items to
change these values:
The Setup screen
The application resource file