Verifying Connectivity

Data Refreshes

You can verify that the Proxy Agent is connected to the PBX while Fault
Management is running by refreshing the PBX data.
Fault Management can refresh PBX data only if the Proxy Agent is
connected to the PBX. Therefore, if a refresh fails, the Proxy Agent may
have lost contact with the PBX.

Refreshing Data Manually

Use the following steps to refresh data manually:
1. Access the Switch View screen.
2. Select one of the following options from the menu bar:
Fault, then select Refresh Bulletin Board
Fault, then select Refresh Alarms and Errors
Configuration, then select Refresh Configuration Data
If ...
The refresh succeeds
A pop-up window displays a message stating
that the refresh has failed

The MIB

You can verify that the Proxy Agent is connected to the PBX by viewing the
status of the g3connectState field in your MIB.
To access the g3connectState field, follow these steps:
1. Starting on your configuration map, select the DEFINITY icon for the PBX
that you want to check.
Then the
connection is ...
Up
Down