Table 4-9. Sw2 Ber Options - AT&T MERLIN LEGEND Release 2.0 Installation Section

Hide thumbs Also See for MERLIN LEGEND Release 2.0:
Table of Contents

Advertisement

Connecting the Control Unit to the Network Interface
Bit-Error Rate Threshold Option
DIP switch SW2 can be set to alarm at bit-error rate (BER) threshold levels
between 10-4 and 10-9 or can be disabled. Table 4-9 shows the settings for
SW2 for the various thresholds.

Table 4-9. SW2 BER Options

Position
1
2
3
4
5
6
7
8
Switch Settings for Framing in Hybrid/PBX Mode
The framing format for the network and for data terminal equipment can be
either D4 or extended superframe (ESF). DIP switches SW5 and SW6 must be
set according to the following tables to match the framing format for the
network and the equipment. This applies to Hybrid/PBX mode only.
4-22
Installing the Channel Service Unit
10-5
10-6
10-4
up
down
up
up
up
down
up
up
up
up
up
up
u p = non-latching mode; down = latching mode
Threshold Option
10-8
10-7
down
up
down
up
up
down
up
u p
not used (up)
not used (up)
not used (up)
10-9
Disable
down
down
up
up
down
up
up
down

Advertisement