SYMPTOM

Heat Pump Tripping Breaker

Heat Pump Won't Shut Off

Heat Pump Running, Not Cooling

RULE OUT
STEP 1:
If breakers do not trip immediately, then issue is most
Weak breaker
likely a weak breaker. Have an electrician confirm
breakers are in good condition and properly sized for
heat pump.
STEP 2:
Multiple heat pumps installed at the same site require
special automatic sequencing controllers to avoid
Incorrect heat
excessive power drops at start-up. Call heat pump
pump power
installer or AquaCal AutoPilot Customer Support for
sequence
further assistance on this type of equipment. See
"Automatic Sequencing Controller" in "Available
Accessories" on page 37 for more information.
STEP 3:
With heat pump off, open access panels to view
compressors. Turn on power to each heat pump and
monitor as each compressors starts. They will power
on in stages. Determine if breaker trips as a
compressor turns on.
Faulty
If fault occurs when a compressor turns on, service
compressor
will be required to determine compressor issue and
why compressor has failed. PLEASE NOTE –
compressor failure is extremely rare. Compressor
failure must be determined before compressor
replacement is considered. Call heat pump installer
or AquaCal AutoPilot Customer Support for further
assistance on this type of repair.
STEP 1:
If an external controller is being used, confirm heat
pump is set to accept the controller's signal. See
section entitled "External Controls / Equipment" on
page 22 and "Configuring for External Controller" on
page 25 for more information.
External
Determine if external controller has its own
controller being
thermostats. If yes, then heat pump mode must be
used improperly
set to "OFF".
If heat pump is set correctly to accept an external
controller's signal to turn off, then contact the
installer of the external controller device or the
device's manufacturer for further assistance.
STEP 2:
Confirm the heat pump mode is set to "OFF". See
Incorrect mode
"Setting Operating Mode" on page 4 for more
setting
information.
STEP 3:
Call heat pump installer or AquaCal AutoPilot Customer
Support for further assistance.
STEP 1:
Measure the temperature of the discharge air coming
Heat pump not
out of the top of the heat pump. If the discharge air is
moving heat out
between 9° to 12° F warmer than the ambient air
temperature, then the heat pump is moving heat out of
the water.
RESOLUTION