Pim_Info Action - HP Model 715/100XC - Workstation Handbook

Hp 9000 series 700 model 715 workstations service handbook (a2600-90039)
Hide thumbs Also See for Model 715/100XC - Workstation:
Table of Contents

Advertisement

Check Type
Cache Check Bus Check
Word
Word
0x80000000
0x40000000
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
Note 1
When more than one failed FRU is identified, run the appropriate
diagnostics to isolate the failed FRU.
Note 2
For the Model 715/75, replace the PCX-T module. For other models,
replace the Motherboard. See HPMC Caused by a Data Cache Parity Error
for more information.
Note 3
While Architected Main Memory space is from 0x00000000 through
0xEFFFFFFF, Model 715 can only use up to 256 MB. With this limitation
any memory address from 0x10000000 through 0xEFFFFFFF is invalid,
and, if given in the System Responder word, the Motherboard should be
(usually) replaced. If the error occurs again, there is a probable Kernel
problem. See HPMC Caused by a Multi-Bit Memory Parity Error for
information on identifying the failed SIMM.
Note 4
There are two possible sources of failure. First, replace the EISA controller.
If the error occurs again, replace the Motherboard.
4–24
Troubleshooting
Table 4–6. PIM_INFO Action Table
Word
N/A
0X00210003
0x00310007
0x00310007
0x00310007
0x00310007
0x00310007
System
Action *
Responder
See Note 1
Word
N/A
See Note 2
0X00000000
Replace SIMM
0xEFFFFFFF
See Note 3
0xF0000000
Replace
0xF7FFFFFF
Motherboard
0xF8000000
Replace Optional
0xFBFFFFFF
Graphics Card in
EISA Slot.
0xFC000000
See Note 4
0xFFBFDFFF
0xFFFBE000
See Note 2
0xFFFBEFFF
0xFFFBF000
Replace
0xFFFFFFFF
Motherboard