Diagnostic Test - Whirlpool HE2t - 3.7 cu. Ft. Front Load Washer User Manual

User guide
Table of Contents

Advertisement

DIAGNOSTIC TEST

The complete built-in service diagnostic mo-
dule contains two entry modes and three
modes of operation.
Entry modes:
Universal mode across all products. It
displays error history prior to performing
any automated test.
Quick entry and bypasses the displaying of
error codes.
Operation modes:
Display the error states that have been
recorded by the appliance.
Run through an automated test.
Run loads to assist in diagnosing potentially
non-electrical issues.
Starting Service History Mode & Diagnostic
Test:
NOTE: The washer must be empty and the
control must be in the OFF state before pres-
sing the touchpad sequence to start the test.
1. Close the door.
2. Select any one key (except PAUSE/
CANCEL) and follow the steps below,
using the same key (remember the key):
Press/hold
Release for
Press/hold
4 seconds
4 seconds
4 seconds
3. Upon release, all console LED lights will
turn on for 5 seconds.
4. If there are any failure codes, all cycle
LED lights will flash and the appropriate
Status LED's will turn on. The Estimated
Time Display will display failure code (if
available).
Release for
Press/hold
4 seconds
4 seconds
6-5
NOTES: This program recalls the most
recent failure code first.
Press the same key to advance to the
next failure code. (If the console doesn't
change then the same failure code was
stored multiple times.)
If there aren't any more failure codes all
the lights on the console will turn on for
5 seconds.
Next the washer begins the Diagnostic
Test.
To cancel out of service mode press
PAUSE/CANCEL. (This exits you out of
the program.)
Starting Diagnostic Test and bypassing
the Service History Mode:
Execute this procedure with an empty drum. All
of the steps below must be done in sequence
in order to reach the Diagnostic Test. This
executes the automatic test but does not show
the error history.
Close the door.
Push POWER.
Select the CLEAN WASHER cycle.
Press EXTRA RINSE four times within
5 seconds.
Press EXTRA RINSE to advance to the
next step of the test procedure.
If the starting procedure fails, push
PAUSE/CANCEL, then repeat the starting
procedure.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents