Figure 27. Intel Raid Bios Console 2 - Spanning Multiple Arrays - Intel AFCSASRISER User Manual

Raid software user guide
Table of Contents

Advertisement

76
7. Select all arrays or disk groups that are to be spanned in the RAID 10, 50, or 60 array by
holding down the <Ctrl> key and selecting each array/disk group in the right pane.
8. Click Next.
9. In the next screen, click Add to SPAN to move all arrays from the left pane to the right
pane. Use <Ctrl> to select all SPANs on the right pane.
10. Click Next.
11. At the Virtual Drive Definition (VD Definition) screen, select either RAID 10, RAID
50, or RAID 60 from the RAID Level drop-down.
RAID 10 is illustrated below.
12. Select the appropriate Stripe Size, Access Policy, Read Policy, Write Policy, IO Policy,
Disk Cache Policy, and Enable/Disable BGI for your application.
For information about setting these parameters, see
page
80.
13. Set the drive size to a number in MB that is a size greater then the size of the RAID 1,
RAID 5, or RAID 6 size listed in the disk group.
Figure 27. Intel
14. Click Next if the application does not automatically progress to the next screen.
®
RAID BIOS Console 2 – Spanning Multiple Arrays
"Setting Drive Parameters" on
®
Intel
RAID Software User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents