Maximizing Performance; Table 10. Raid Levels And Performance - Intel AFCSASRISER User Manual

Raid software user guide
Table of Contents

Advertisement

RAID
Level
6
10
50
60

Maximizing Performance

A RAID disk subsystem improves I/O performance. The RAID array appears to the host
computer as a single storage unit or as multiple virtual units. I/O is faster because drives can be
accessed simultaneously.
RAID
Level
0
1 or
IME
20
Combines distributed parity with disk striping. RAID 6 can sustain two drive failures and
still maintain data integrity. Parity provides redundancy for two drive failures without
duplicating the contents of entire disk drives. If a drive fails, the RAID controller uses the
parity data to reconstruct all missing information. In RAID 6, this method is applied to
entire drives or stripes across all drives in an array. Using distributed parity, RAID 6
offers fault tolerance with limited overhead.
Provides complete data redundancy using striping across spanned RAID 1 arrays. RAID
10 works well for any environment that requires the 100 percent redundancy offered by
mirrored arrays. RAID 10 can sustain a drive failure in each mirrored array and maintain
drive integrity.
Provides data redundancy using distributed parity across spanned RAID 5 arrays. RAID
50 includes both parity and disk striping across multiple drives. If a drive fails, the RAID
controller uses the parity data to recreate all missing information. RAID 50 can sustain
one drive failure per RAID 5 array and still maintain data integrity.
Provides data redundancy using distributed parity across spanned RAID 6 arrays. RAID
60 can sustain two drive failures per RAID 6 array and still maintain data integrity. It
provides the highest level of protection against drive failures of all of the RAID levels.
RAID 60 includes both parity and disk striping across multiple drives. If a drive fails, the
RAID controller uses the parity data to recreate all missing information.
Table 10

Table 10. RAID Levels and Performance

RAID 0 (striping) offers the best performance of any RAID level. RAID 0 breaks up data
into smaller blocks, then writes a block to each drive in the array. Disk striping writes data
across multiple drives instead of just one drive. It involves partitioning each drive storage
space into stripes that can vary in size from 8 KB to 128 KB. These stripes are
interleaved in a repeated sequential manner. Disk striping enhances performance
because multiple drives are accessed simultaneously.
With RAID 1 or IME (mirroring), each drive in the system must be duplicated, which
requires more time and resources than striping. Performance is impaired during drive
rebuilds.
Fault Tolerance
describes the performance for each RAID level.
Performance
®
Intel
RAID Software User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents