Enclosure Management; Performance - Intel AFCSASRISER User Manual

Raid software user guide
Table of Contents

Advertisement

Data protection is also provided by running calculations on the drives to make sure data is
consistent and that drives are good. The controller uses consistency checks, background
initialization, and patrol reads. You should include these in regular maintenance schedules.

Enclosure Management

Enclosure management is the intelligent monitoring of the disk subsystem by software or
hardware usually within a disk enclosure. It increases the ability for the user to respond to a
drive or power supply failure by monitoring those sub systems.

Performance

Performance improvements come from multiple areas including disk striping and disk
spanning, accessing multiple disks simultaneously, and setting the percentage of processing
capability to use for a task.
Disk Striping
Disk striping writes data across all of the physical disks in the array into fixed size partitions or
stripes. In most cases, the stripe size is user-defined. Stripes do not provide redundancy but
improve performance since striping allows multiple physical drives to be accessed at the same
time. These stripes are interleaved in a repeated sequential manner and the controller knows
where data is stored. The same stripe size should be kept across RAID arrays.
Terms used with strip sizing are listed below.
6
"ABCsum". When drive A fails, the controller uses the ABCsum to calculates what
remains on drives B+C. The remainder must be recreated onto new drive A.
Parity can be dedicated (all parity stripes are placed on the same drive) or distributed
(parity stripes are spread across multiple drives). Calculating and writing parity slows
the write process but provides redundancy in a much smaller space than mirroring.
Parity checking is also used to detect errors in the data during consistency checks and
patrol reads.
RAID 5 uses distributed parity and RAID 6 uses dual distributed parity (two different
sets of parity are calculated and written to different drives each time.) RAID modes 1
and 5 can survive a single disk failure, although performance may be degraded,
especially during the rebuild. RAID modes 10 and 50 can survive multiple disk failures
across the spans, but only one failure per array. RAID mode 6 can survive up to two disk
failures. RAID mode 60 can sustain up to two failures per array.
The consistency check operation verifies that data in the array matches the redundancy
data (parity or checksum). This is not provided in RAID 0 in which there is no
fault tolerance.
Background initialization is a consistency check that is forced five minutes after the
creation of a virtual disk. Background initialization also checks for media errors on
physical drives and ensures that striped data segments are the same on all physical drives
in an array.
Patrol read checks for physical disk errors that could lead to drive failure. These checks
usually include an attempt at corrective action. Patrol read can be enabled or disabled
with automatic or manual activation. This process starts only when the RAID controller
is idle for a defined period of time and no other background tasks are active, although a
patrol read check can continue to run during heavy I/O processes.
®