174
Number
Type
0
Info
Firmware initialization started (PCI ID %04x/%04x/%04x/%04x)
1
Info
Firmware version %s
2
Fatal
Unable to recover cache data from TBBU
3
Info
Cache data recovered from TBBU successfully
4
Info
Configuration cleared
5
Warning
Cluster down; communication with peer lost
6
Info
Virtual drive %s ownership changed from %02x to %02x
7
Info
Alarm disabled by user
8
Info
Alarm enabled by user
9
Info
Background initialization rate changed to %d%%
10
Fatal
Controller cache discarded due to memory/battery problems
11
Fatal
Unable to recover cache data due to configuration mismatch
12
Info
Cache data recovered successfully
13
Fatal
Controller cache discarded due to firmware version incompatibility
14
Info
Consistency Check rate changed to %d%%
15
Dead
Fatal firmware error: %s
16
Info
Factory defaults restored
17
Info
Flash downloaded image corrupt
18
Critical
Flash erase error
19
Critical
Flash timeout during erase
20
Critical
Flash error
21
Info
Flashing image: %s
22
Info
Flash of new firmware image(s) complete
23
Critical
Flash programming error
24
Critical
Flash timeout during programming
25
Critical
Flash chip type unknown
26
Critical
Flash command set unknown
27
Critical
Flash verify failure
28
Info
Flush rate changed to %d seconds
29
Info
Hibernate command received from host
30
Info
Event log cleared
31
Info
Event log wrapped
32
Dead
Multi-bit ECC error: ECAR=%x
33
Warning
Single-bit ECC error: ECAR=%x
34
Dead
Not enough controller memory
35
Info
Patrol Read complete
36
Info
Patrol Read paused
37
Info
Patrol Read Rate changed to %d%%
38
Info
Patrol Read resumed
39
Info
Patrol Read started
40
Info
Rebuild rate changed to %d%%

Table 14. MFI Messages