The following figure shows a RAID 6 data layout. The second set of parity drives are denoted
by Q. The P drives follow the RAID 5 parity scheme.
Note: When only three hard drives are available for RAID 6, the situation has to be that P equals Q equals
original data, which means that the three hard drives have the same original data, which can afford
two disk failures.
®
Intel
RAID Software User's Guide
Provides a high level of data protection through the use of a second parity block in
each stripe. Use RAID 60 for data that requires a very high level of protection from
loss.
In the case of a failure of one drive or two drives in a RAID set in a virtual disk, the
RAID controller uses the parity blocks to recreate all the missing information. If
Uses
two drives in a RAID 6 set in a RAID 60 virtual disk fail, two drive rebuilds are
required, one for each drive. These rebuilds do not occur at the same time. The
controller rebuilds one failed drive, and then the other failed drive.
Use for office automation, online customer service that requires fault tolerance or
for any application that has high read request rates but low write request rates.
Provides data redundancy, high read rates, and good performance in most
environments. Each RAID 6 set can survive the loss of two drives or the loss of a
drive while another drive is being rebuilt. Provides the highest level of protection
Strong Points
against drive failures of all of the RAID levels. Read performance is similar to that
of RAID 50, though random reads in RAID 60 might be slightly faster because
data is spread across at least one more disk in each RAID 6 set.
Not well suited to tasks requiring a lot of writes. A RAID 60 virtual disk has to
generate two sets of parity data for each write operation, which results in a
significant decrease in performance during writes. Disk drive performance is
Weak Points
reduced during a drive rebuild. Environments with few processes do not perform
as well because the RAID overhead is not offset by the performance gains in
handling simultaneous processes. RAID 6 costs more because of the extra
capacity required by using two parity blocks per stripe.
Drives
A minimum of 6.