HP L1000 - 9000 - 0 MB RAM Manual page 45

Carrier grade addendum - rp5400 series of servers
Hide thumbs Also See for L1000 - 9000 - 0 MB RAM:
Table of Contents

Advertisement

3. Remove the T-15 mounting screw located to the right of the handle near the top of the power
supply.
WARNING
Use care when removing power supplies from the server. the supplies are heavier
than they appears. Failure to follow this precaution can result in damage to
equipment and injury to personnel.
4. Grasp the handle and pull the power supply out of the server.
5. Grasp the handle in one hand and support the power supply with the other.
Figure 2-2
Removing a Power Supply
Step 4.
Install a power supply into the server.
1. Grasp the handle in one hand, support the power supply with the other, and slide the power
supply into the server.
NOTE
The Power Supply LED should illuminate immediately.
2. Connect the short DC power cable connector to the connector on the seismic rack tray beneath
the server. The Power Supply LED should illuminate immediately.
3. Install the T-15 mounting screw located to the right of the handle near the top of the power
supply.
4. Reinstall the slide cover bracket on the front of the seismic enclosure mounting tray.
Chapter 2
Removal and Replace Procedures
Removing and Replacing Hotswap DC Power Supplies
33