Installing The Utility - HP ProLiant DL360p Reference Manual

Configuring arrays on hp smart array controllers reference guide
Hide thumbs Also See for ProLiant DL360p:
Table of Contents

Advertisement

Field
SSD Wear Status
Power Cycles
Power On Hours
Estimated Life
Remaining Based On
Workload To Date
Usage Remaining
SSD Utilization

Installing the utility

Browse to the HP Array Configuration Utility website
1.
(http://h18004.www1.hp.com/products/servers/proliantstorage/software-management/acumatrix
/index.html).
Click Download software.
2.
Select an OS.
3.
Identify the preferred software and version, and then click Download.
4.
Save, and then run, the executable file.
5.
By default, the software installs at C:\Program Files\HP System Tools\.
Description
Indicates the SSD's wear status with one of the following
messages:
OK
Not Supported
The SmartSSD Wear Gauge log is full. Wear
Gauge parameters are not available.
SSD has less than 5% usage remaining before
wearout.
SSD has less than 2% usage remaining before
wearout.
SSD has less than an estimated 56 days before it
reaches the maximum usage limit for writes
(wearout) and should be replaced as soon as
possible.
SSD has less than 5% of usage remaining before
wearout. It has less than an estimated 56 days
before it reaches the maximum usage limit and
should be replaced as soon as possible.
SSD has less than 2% of usage remaining before
wearout. It has less than an estimated 56 days
before it reaches the maximum usage limit and
should be replaced as soon as possible.
SSD has reached the maximum rated usage limit for
writes (wearout) and should be replaced
immediately.
Indicates the number of times the SSD has powered on
from the powered off state
Indicates the number of hours the SSD has been
powered on
Indicates an estimate of the number of days the SSD has
before SSD Utilization reaches 100%. This field is not
displayed when the SSD Utilization is still at 0%.
Indicates the percentage of the SSD that has not worn
out. Usage remaining is equal to the difference of 100
and the SSD Utilization percentage.
Indicates the percentage of the SSD that has worn out
HP Array Diagnostics and SmartSSD Wear Gauge Utility 98

Advertisement

Table of Contents
loading

Table of Contents