HP ProLiant DL360p Reference Manual page 78

Configuring arrays on hp smart array controllers reference guide
Hide thumbs Also See for ProLiant DL360p:
Table of Contents

Advertisement

NoBatteryWriteCache (on page 79)
PreferredPathMode (on page 79)
QueueDepth
("Video performance
RaidArrayId (on page 79)
ReadCache
("ReadCache,
RebuildPriority
("RebuildPriority,
SurfaceScanDelay (on page 80)
SurfaceScanDelayExtended (on page 80)
WriteCache
("ReadCache,
Controller
You must enter a value for this option because it identifies the controller that you want to configure:
All—Configure all detected controllers in the system.
First—Configure the first controller found, based on the controller with the lowest PCI slot number.
Internal controllers are used before external controllers.
The -internal and -external command line switches influence what ACU regards as the First
controller. For example, if you use the -external switch, the First controller is the first external
controller discovered, regardless of the number of internal controllers in the host system.
Slot [N][:M]—Configure the internal controller in slot number N, or the external controller at port
M in slot N.
WWN [N]—Configure the external controller that has the World Wide Name N.
SerialNumber [N]—Configure the shared storage controller that has serial number N.
IOCabinet[N],IOBay[N],IOChassis[N],Slot[N],Cabinet[N],Cell[N]—Configure
the controller in the Integrity server that has the slot path information defined by this sequence of
identifiers.
CacheState
This option enables you to flush the cache or disable flushing of the cache. Values are FlushEnable and
FlushDisable.
You can use this option to prevent stale cache issues.
ClearConfigurationWithDataLoss
Clearing the configuration causes data loss because it deletes all logical volumes and arrays on the
controller. If you clear a configuration, you can write commands later in the script file to create a new
configuration from the liberated drive capacity.
The values for this option are Yes or No. The default value is No.
DriveWriteCache
This option controls the settings of the write cache for all connected physical disks. For this option, the setting
is Enable or Disable. Not all physical disks or controllers support this option.
options" on page 80)
WriteCache" on page 79)
ExpandPriority" on page 80)
WriteCache" on page 79)
HP Array Configuration Utility 78