HP ProLiant DL360p Reference Manual page 76

Configuring arrays on hp smart array controllers reference guide
Hide thumbs Also See for ProLiant DL360p:
Table of Contents

Advertisement

HBA category (on page 87)
Each category has several scripting options, but you do not always need to assign values to every option.
ACU can use default values in some instances, while in other instances, a listed option might not be relevant
for a particular configuration or scripting mode.
The options for each category are listed in the following table and described in more detail in the remainder
of this section.
Category
Options
Action
Control
Method
Controller
Controller
CacheState
ClearConfigurationWithDataLoss
DeleteLicenseKey
DPOEnable
DriveWriteCache
ElevatorSortEnable
ExpandPriority
IRPEnable
LicenseKey
MNPDelay
NoBatteryWriteCache
PreferredPathMode
QueueDepth
RaidArrayId
ReadCache
RebuildPriority
SurfaceScanDelay
SurfaceScanDelayExtended
SurfaceScanMode
WriteCache
Array
Array
Drive
DriveType
Join
OnlineSpare
Split
Logical Drive ArrayAccelerator
LogicalDrive
NumberOfParityGroups
PreferredPath
RAID
Renumber
Repeat
ResourceVolumeOwner
Sectors
ShrinkSize
Size
SizeBlocks
StripSize
StripeSize
Description
These options define the overall behavior of ACU when it
processes scripts and creates configurations. Control
options can occur only once in a script file and must be
listed first.
Options in this category specify the controller that is to be
configured (or the controller that had its configuration
captured). Although the Controller option must begin this
section of the script, you can script other options in this
category in any order.
You can use one script file to configure all controllers in a
system, and you can configure the controllers identically
or individually. If you define each controller configuration
individually, enter the option values for one controller
and its arrays and logical drives before specifying the
option values for another controller.
These options describe an array that is to be configured
on the controller that was previously specified in the
script. (If no controller was previously specified, ACU
stops processing the script and creates an error file.)
Although the Array option must begin this section of the
script, you can script the other options in this category in
any order.
These options describe a logical drive that is to be
configured on an array that was previously specified in
the script. (If no array was previously specified, ACU
stops processing the script and creates an error file.)
Although the LogicalDrive option must begin this section
of the script, you can script the other options in this
category in any order.
HP Array Configuration Utility 76