HP StorageWorks 2405 - Disk System User Manual page 106

Hp storageworks disk system 2405 user's guide(this manual also covers the hp surestore disk system 2405)
Hide thumbs Also See for StorageWorks 2405 - Disk System:
Table of Contents

Advertisement

Table 13.
Troubleshooting Table
Problem
HW Event
Description
Category
Temperature is
Critical
over limit
Major Warning
Temperature sensors are on the LCC and are independent of
power supplies. Investigate temperature warnings
immediately, before power supplies sense critical temperature
and turn off.
Temperature is
Critical
under limit
Major Warning
Voltage is over
Critical
limit
Major Warning
Voltage is
Critical
under limit
Major Warning
106 Troubleshooting
LED
STM
State
Status
none
Critical
Temp is
>54.5º C
(130.1º F)
none
Non-critical
Temp is
>36º C
(96.8º F)
none
Critical
Temps
<9.5º C
(49.1º F)
none
Non-critical
Temps
<15.5º C
(59.9º F)
none
Critical
none
Non-critical
none
Critical
none
Non-critical
Probable Cause/Solution
A fan is faulty. Check status and
correct.
Airflow is obstructed; vents are
blocked.
One or more slots are empty.
Power supply is faulty. Check status
and correct.
Room temperature is too high. If
ambient temperature cannot be
reduced in a reasonable time, turn off
product to prevent shortened life.
Temperature sensor is faulty.
Compare temperature reported by peer
LCC.
Room temperature is too low.
Temperature sensor is faulty.
Compare temperature reported by peer
LCC.
Power supply is faulty. Check status and
correct.
Either power supply is faulty. Check
status and correct.