HP StorageWorks 2405 - Disk System User Manual page 103

Hp storageworks disk system 2405 user's guide(this manual also covers the hp surestore disk system 2405)
Hide thumbs Also See for StorageWorks 2405 - Disk System:
Table of Contents

Advertisement

4
After the device files have been created, issue the FCMSUTIL command on
the device files. For example:
/opt/fcms/bin/fcmsutil
The output should appear similar to the following:
Local N_Port_ID is = 0x000001
N_Port Node World Wide Name = 0x10000060B03E22CB
N_Port World Wide Name = 0x10000060B03E22CB
Number of EDB's in use = 0
Number of OIB's in use = 0
Number of Active Outbound Exchanges = 1
Number of Active Login Sessions = 5
A driver state of Ready indicates that the driver is in the correct operating
state. IN_LOOP topology indicates that the host has detected an FC-AL.
5
Check Fibre Channel cables for loose connections.
6
Check the Enclosure ID switches for conflicting loop IDs. Make sure both
LCCs have the same ID setting.
/dev/fcms0
Topology = IN_LOOP
Speed = 1062500000 (bps)
HPA of card = 0xFBF48000
EIM of card = 0xFFFA000A
Driver state = Ready
Troubleshooting 103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks disk system 2405

Table of Contents