Table 61 Syntax requirements for optional parameters (continued)
Parameter
Functional macro (except for
StartHrcPair)
StartHrcPair
Entire check

Error reporting

The scripting error codes are slightly different than the general error codes.
shows the format of the scripting error codes.
messages.
Table 63 (page 127)
ID is the four-digit number displayed on the error message. The internal code is the four-digit number
displayed in the fifth column of the error trace file.
Figure 20 Scripting error code format
Table 62 Error messages
Message
Syntax error
Parameter error
126 Continuous Access Synchronous Z scripting
Syntax requirements
The number of phrases is not less than the minimum count.
Duplicate parameter identification name is prohibited.
The required parameter for the identification name is defined.
The equal sign is described between the right side and the parameter identification
name.
Specifying the right side is correct.
The parameter identification name is described immediately after the macro.
The parameters for the identification names are delimited by a comma (,).
An illegal phrase is not included in any statement.
Check that the number of phrases matches.
Check that the (If) has a matching (EndIf).
Check that the last line in the execution statement terminates at (END).
lists the scripting error codes. In
Conditions to verify
The syntax validity of the script is checked at the
start of execution. An error message will be
displayed if failed.
The parameter validity of the script is checked
on executing each instruction. An error message
will be displayed if failed.
Table 62 (page 126)
describes the scripting error
Table 63 (page 127)
Corrective action
Use the scripting error code to determine which
line contains the syntax error (see
127)), and fix the syntax error.
Use the scripting error code to determine which
line contains the parameter error (see
Table 63 (page
Figure 20 (page 126)
the message
Table 63 (page
127)), and fix the parameter error.